   * All modules are ATmega328-based. It means that, using the Arduino environment you can customize the code running on the boards. ​   * All modules are ATmega328-based. It means that, using the Arduino environment you can customize the code running on the boards. ​
 ===== Measuring the power consumption with emonTx module ===== ===== Measuring the power consumption with emonTx module =====
-The measuring is achieved using the [[http://​openenergymonitor.org/​emon/​modules/​emonTxV3|emonTx v3 board]]. It is powered using a 9v-230v AC-AC adaptator which is recommended to get a best power monitoring accuracy, giving the real power consumption (which is what you get billed for).+The measuring is achieved using the [[http://​openenergymonitor.org/​emon/​modules/​emonTxV3|emonTx v3 board]] ​(see [[http://​wiki.openenergymonitor.org/​index.php?​title=EmonTx_V3|the wiki]]). It is powered using a 9v-230v AC-AC adaptator which is recommended to get a best power monitoring accuracy, giving the real power consumption (which is what you get billed for).
   * In the building we have a three-phase electric power installation. ​   * In the building we have a three-phase electric power installation. ​
   * The power is measured using three [[http://​openenergymonitor.org/​emon/​buildingblocks/​ct-sensors-introduction|CT (Current Transformer) clips]]. The neutral wire of the electrical panel is not connected (Note : with a single phase electric power you should connect two wires : the neutral and the power line ones).\\ {{:​projects:​open_energy_monitor_unmonastery:​oem_ct_electrical_panel.jpg?​200|}} {{:​projects:​open_energy_monitor_unmonastery:​oem_emontx_wiring.jpg?​200|}}   * The power is measured using three [[http://​openenergymonitor.org/​emon/​buildingblocks/​ct-sensors-introduction|CT (Current Transformer) clips]]. The neutral wire of the electrical panel is not connected (Note : with a single phase electric power you should connect two wires : the neutral and the power line ones).\\ {{:​projects:​open_energy_monitor_unmonastery:​oem_ct_electrical_panel.jpg?​200|}} {{:​projects:​open_energy_monitor_unmonastery:​oem_emontx_wiring.jpg?​200|}}